ABB, 2CDS282001R0104, Miniature Circuit Breaker - S200P - 2P - C - 10 ampere

(0 reviews)

Sold by:
Inhouse product

Price:
AED126.37 /pcs

Quantity:
(3 available)

Total Price:
Share:
  • MAIN SPECIFICATION
    ABB Global IDABB2CDS282001R0104
    Business Area (Master Data) NameElectrification
    Catalog DescriptionS202P-C10 Miniature Circuit Breaker C-Char.,25kA,10A,2P
    Division (Master Data) NameSmart Buildings
    EAN4016779590426
    Rated Insulation Voltage (Ui)acc. to IEC/EN 60664-1 440 volt
    SKU ID2CDS282001R0104
    TECHNICAL
    Accessories AvailableYes
    Actuator MarkingI / O
    Actuator MaterialInsulation Group II, Black, Sealable
    Connecting CapacityBusbar 10 / 10 mm²
    Flexible with Ferrule 0.75 ... 16 mm²
    Flexible 0.75 ... 16 mm²
    Rigid 0.75 ... 25 mm²
    Stranded 0.75 ... 25 mm²
    Contact Position IndicationRed ON / Green OFF
    Dielectric Test Voltage50/60 Hz, 1 min: 2 kV
    Electrical Endurance20000 AC cycle
    Energy Limiting Class3
    Housing MaterialInsulation Group II, RAL 7035
    Installation Sizeacc. to DIN 43880 1
    Mechanical Endurance (Nendu)20000 cycle
    Mounting On DIN RailTH35-7.5 (35 x 7.5 mm Mounting Rail) acc. to IEC 60715
    TH35-15 (35 x 15 mm Mounting Rail) acc. to IEC 60715
    Mounting PositionAny
    Number Of Protected Poles2
    Overvoltage CategoryIII
    Pollution Degree3
    Power Loss2.8 W
    at Rated Operating Conditions per Pole 1.4 W
    Power Supply ConnectionArbitrary
    Product NameMiniature Circuit Breaker
    Product RangeS200P
    Rated Frequency (f)50 / 60 Hz
    Recommended Screw DriverPozidriv 2
    Screw Terminal TypeFailsafe Bi-directional Cylinder-lift Terminal
    StandardsCSA 22.2 No. 235
    IEC/EN 60898-1
    IEC/EN 60947-2
    UL 1077
    Terminal TypeScrew Terminals
    Tightening Torque2.8 N·m
    TECHNICAL UL/CSA
    Connecting Capacity UL/CSABusbar 18-8 AWG
    Conductor 18-4 AWG
    Interrupting Rating Acc. To UL1077(480 V AC) 10 kA
    (480Y / 277 V AC) 10 kA
    Maximum Operating Voltage UL/CSA480Y/277 V AC
    Tightening Torque UL/CSA25 in·lb
    DIMENSIONS
    Built-In Depth (t2)69 mm
    Pole Net Weight0.14 kg
    ORDERING
    Minimum Order Quantity1 piece
    Selling Unit Of Measurepiece
    ENVIRONMENTAL
    Environmental Conditions28 cycles
    with 55 °C / 90-96 %
    and 25 °C / 95-100 %
    Reference Ambient Air Temperature30 °C
    Resistance To Shock Acc. To IEC 60068-2-2725g / 2 shocks / 13 ms
    Resistance To Vibrations Acc. To IEC 60068-2-65g, 20 cycles at 5 ... 150 ... 5 Hz with load 0.8 In
    RoHS StatusFollowing EU Directive 2011/65/EU
    CLASSIFICATIONS
    CN88536 20 10
    E-Number (Finland)3216140
    E-Number (Sweden)2102125
    EClassV11.0 : 27141901
    EPLAN Catalog TreeElectrical engineering / Protection devices / General
    EPLAN Function DefinitionCircuit breaker / Double circuit-breaker / Double circuit breaker 1_2_3_4
    ETIM 6EC000042 - Miniature circuit breaker (MCB)
    ETIM 7EC000042 - Miniature circuit breaker (MCB)
    ETIM 8EC000042 - Miniature circuit breaker (MCB)
    Object Classification CodeF
    UNSPSC39121614
    WEEE B2C / B2BBusiness To Consumer
    POPULAR DOWNLOADS
    EPLAN Graphical Macro9AKK106713A8119
    EPLAN Macro9AKK106713A8117
    OTHER
    Ambient Air TemperatureOperation -25 ... +55 °C
    Storage -40 ... +70 °C
    Degree Of ProtectionIP20
    Enclosure with Cover IP40
    Input Voltage TypeAC/DC
    Number Of Poles2
    Operational VoltageMaximum (Incl. Tolerance) 125 V DC
    Maximum (Incl. Tolerance) 440 V AC
    Minimum 12 V AC
    Minimum 12 V DC
    Product Net Width35
    Rated Conditional Short-Circuit Current (Inc)(230 V) 25 kA
    (400 V) 40 kA
    Rated Current (In)10 A
    Rated Impulse Withstand Voltage (Uimp)4 kilovolt
    at 2000 m 5 kilovolt
    at Sea Level 6.2 kilovolt
    Rated Operational Voltageacc. to IEC 60898-1 400 V AC
    acc. to IEC 60947-2 400 V AC
    Rated Service Short-Circuit Breaking Capacity (Ics)(400 V AC) 12.5 kA
    Rated Short-Circuit Capacity (Icn)(230 V AC) 25 kA
    (400 V AC) 25 kA
    Rated Ultimate Short-Circuit Breaking Capacity (Icu)(230 V AC) 25 kA
    (400 V AC) 25 kA
    Rated Voltage (Ur)400 V AC
    Tripping CharacteristicC
    WEEE Category5. Small Equipment (No External Dimension More Than 50 cm)
    Width In Number Of Modular Spacings2
There have been no reviews for this product yet.

Product Queries (0)

Login or Registerto submit your questions to seller

Other Questions

No none asked to seller yet

Whatsapp