Measuring principle : Differential pressure
Characteristic : Digital transmitter with metallic measuring diaphragms
Modular transmitter
Long-term stability
High static pressure/Overload resistance
Secondary process barrier
Supply voltage : 4...20 mA HART
10,5...45V DC (Non Ex):
Ex ia: 10,5...30V DC
PROFIBUS PA:
9...32 V DC (Non Ex)
FOUNDATION Fieldbus:
9...32 V DC (Non Ex)
Reference Accuracy : Standard: 0.05%
Platinum: up to 0.035%
Long term stability : 0.03 % of URL/ year
0.05 % of URL/ 5 years
0.08 % of URL/ 10 years
Process temperature : -40°C...85°C
(-40°F...185°F)
Ambient temperature : -50°C...85°C
(-58°F...185°F)
Measuring cell : 10 mbar...250 bar
(0.15 psi...3750 psi)
Smallest calibratable span : 1 mbar (0.015 psi)
Vacuum resistance : 50 mbar (0.73 psi)
Max. Turn down : 100:1
Max. overpressure limit : On one side:
420 bar
(6300psi)
Process connection : 1/4-18NPT
RC1/4"
Material process membrane : 316L, AlloyC,
Tantal,
Gold-Rhodium
Material gasket : Viton, PTFE, EPDM, NBR
Fill fluid : Silicone oil
Inert oil
Material housing : 316L, Die-cast aluminum
Communication : 4...20 mA HART
PROFIBUS PA
FOUNDATION Fieldbus
Certificates / Approvals : ATEX, FM, CSA, CSA C/US, IEC Ex, INMETRO, NEPSI, EAC, UK Ex
Safety approvals : SIL
Design approvals : NACE MR0103
EN10204-3.1
Marine approvals : GL/ ABS
Specialities : Diagnostic functions
Successor : PMD75B