Type code | SIEH |
Conforms to standard | EN 60947-5-2 |
Symbol | 00991701 |
Certification | RCM compliance mark c UL us - Listed (OL) |
CE marking (see declaration of conformity) | As per EU EMC directive |
Note on materials | Free of copper and PTFE |
Rated operating distance | 6 mm |
Assured operating distance | 4.86 mm |
Reduction factors | Aluminum = 1.0 Stainless steel, 1 mm thick = 0.45 Stainless steel, 2 mm thick = 0.9 Copper = 0.85 Brass = 1.3 Steel St 37 = 1.0 |
Ambient temperature | -25 °C ... 70 °C |
Switching output | PNP |
Switching element function | N/O contact |
Reproducibility, switching value FS | 0.3 mm |
Hysteresis | ≤ 0.73 mm |
Max. switching frequency | 600 Hz |
Max. output current | 200 mA |
Voltage drop | 2 V |
Inductive protective circuit | Installed Output current < 100 mA and switching frequency < 10 Hz |
Short-circuit protection | Pulsed |
DC operating voltage range | 10 V ... 30 V |
Residual ripple | 20 % |
Idle current | < 12 mA |
Reverse polarity protection | for all electrical connections |
Electrical connection | 3-pin M12x1 Plug |
Size | M12 |
Type of mounting | With lock nut |
Mounting type | Flush |
Product weight | 28 g |
Housing material | High-alloy steel |
Switching status indication | LED yellow |
Ambient temperature with flexible cable installation | -5 °C ... 70 °C |
Degree of protection | IP67 IP69K |
Resistance to sensor fitting pressure | 80 bar |
Corrosion resistance class (CRC) | 2 - Moderate corrosion stress |
Selection of additional sensor information | With increased switching distance |
Electrical output | PNP |
Selection of sensor version | Fully stainless steel housing |