Flow sensor SFAB-10U-HQ6-2SV-M12 (565386)

(0 reviews)

Sold by:
Inhouse product

Price:
AED2,355.36 /pcs

Quantity:
(7 available)

Total Price:
Share:
  • Symbol00992242
  • ApprovalRCM trademark c UL us - Recognized (OL)
  • CE mark (see declaration of conformity)To EU EMC Directive In accordance with EU RoHS Directive
  • CE marking (see declaration of conformity)To UK instructions for EMC To UK RoHS instructions
  • Certificate issuing authorityUL E322346
  • Note on materialsRoHS-compliant
  • Measured variableVolume Volumetric flow rate
  • Flow directionUnidirectional P1 -> P2
  • Measuring principleThermal
  • Measurement methodHeat Loss
  • Start value for flow rate measuring range0.1 l/min
  • End value for flow rate measuring range10 l/min
  • Operating pressure0 MPa ... 1 MPa
  • Operating pressure0 bar ... 10 bar
  • Operating mediumCompressed air to ISO 8573-1:2010 [6:4:4] Nitrogen
  • Media temperature0 °C ... 50 °C
  • Ambient temperature0 °C ... 50 °C
  • Nominal temperature23 °C
  • Accuracy of flow rate± (3% o.m.v. + 0.3% FS)
  • Repetition accuracy offset in ± %FS0.2 %FS
  • Repetition accuracy span in ± %FS0.8 %FS
  • Temperature coefficient span in ± %FS/KTyp. 0.1%FS/K
  • Pressure influence span in ± %FS/bar0.5 %FS/b.
  • Switching output2 x PNP or 2 x NPN, switchable
  • Switching functionWindow comparator Threshold value comparator
  • Switching element functionN/C or N/O contact, switchable
  • Max. output current100 mA
  • Analogue output0 - 10 V
  • Flow characteristic curve start value0 l/min
  • Flow characteristic curve end value10 l/min
  • Output characteristic curve start value0 V
  • Output characteristic curve end value10 V
  • Min. load resistance voltage output10 kOhm
  • Short circuit current ratingyes
  • Overload protectionAvailable
  • Operational voltage range DC15 V ... 30 V
  • No-load supply current120 mA
  • Reverse polarity protectionFor all electrical connections
  • Electrical connection 1, connection typePlugs
  • Electrical connection 1, connector systemM12x1, A-coded to EN 61076-2-101
  • Electrical connection 1, number of connections/cores5
  • Electrical connection 1, connection pattern00995383
  • Type of mountingWith through-hole With H-rail
  • Mounting positionoptional
  • Pneumatic connectionFor tubing O.D. 6 mm
  • Product weight160 g
  • Material housingPA-reinforced
  • Display typeIlluminated LCD, multi-colour
  • Displayable unitsl l/h l/min m3 scf scfm
  • Setting optionsTeach-in Via display and keys
  • Protection against tamperingPIN code
  • Degree of protectionIP65
  • Pressure drop<100 mbar
  • Protection classIII
  • Corrosion resistance class CRC2 - Moderate corrosion stress
  • LABS (PWIS) conformityVDMA24364-B1/B2-L