Schneider Electric, LV438699, Circuit breaker, ComPact NSX160F AC/DC, 18kA/415VAC, TMD trip unit 125A, 2 poles 2d

(0 reviews)

Sold by:
Inhouse product

Price:
AED267.96 /pc

Quantity:
(2 available)

Total Price:
Share:
Main
RangeComPacT new generation
Product nameComPacT NSX new generation
Device short nameNSX160F
Product or component typeCircuit breaker
Device applicationDistribution
Poles description2P
Protected poles description2D
[In] rated current125 A at 40 °C
[Ue] rated operational voltage690 V AC 50/60 Hz
500 V DC
Network typeAC
DC
Network frequency50/60 Hz
Suitability for isolationYes conforming to EN/IEC 60947-2
utilisation categoryCategory A
[Icu] rated ultimate short-circuit breaking capacity36 kA Icu at 220/240 V AC 50/60 Hz conforming to IEC 60947-2
18 kA Icu at 380/415 V AC 50/60 Hz 1P conforming to IEC 60947-2
15 kA Icu at 440 V AC 50/60 Hz 1P conforming to IEC 60947-2
10 kA Icu at 500/525 V AC 50/60 Hz 2P conforming to IEC 60947-2
5 kA Icu at 660/690 V AC 50/60 Hz conforming to IEC 60947-2
36 kA Icu at 250 V DC 50/60 Hz 1 pole conforming to IEC 60947-2
36 kA Icu at 500 V DC 50/60 Hz 2 poles in series conforming to IEC 60947-2
Performance levelF 18 kA 415 V AC
Trip unit nameTM-D
Trip unit technologyThermal-magnetic
Trip unit protection functionsLI
control typeToggle
Circuit breaker mounting modeFixed

Complementary
[Ui] rated insulation voltage750 V AC 50/60 Hz conforming to IEC 60947-2
[Uimp] rated impulse withstand voltage8 kV conforming to IEC 60947-2
[Ics] rated service short-circuit breaking capacity36 kA at 220/240 V AC 50/60 Hz conforming to IEC 60947-2
18 kA at 380/415 V AC 50/60 Hz conforming to IEC 60947-2
15 kA at 440 V AC 50/60 Hz conforming to IEC 60947-2
10 kA at 500/525 V AC 50/60 Hz conforming to IEC 60947-2
5 kA at 660/690 V AC 50/60 Hz conforming to IEC 60947-2
36 kA at 250 V DC 50/60 Hz conforming to IEC 60947-2
36 kA at 500 V DC 50/60 Hz conforming to IEC 60947-2
Mechanical durability20000 cycles
Electrical durability20000 cycles at 277 V In/2
10000 cycles at 277 V In
Power dissipation per pole10.78 W
mounting supportBackplate
Mounting positionHorizontal and vertical
Flat on the back
Upside connectionFront
downside connectionFront
Connection pitch35 mm
Protection typeL : for overload protection (thermal)
I : for short-circuit protection (magnetic)
Trip unit rating125 A at 40 °C
Long-time pick-up adjustment type Ir (thermal protection)Fixed
[Ir] long-time protection pick-up adjustment range1 x In
Long-time protection delay adjustment type trFixed
Instantaneous protection pick-up adjustment type IiFixed
[Ii] instantaneous protection pick-up adjustment range1000 A
earth-leakage protectionWithout
Width (W)70 mm
Height (H)161 mm
Depth (D)86 mm
Net weight1.2 kg

Environment
StandardsEN/IEC 60947
product certificationsCCC
EAC
Marine
Overvoltage categoryClass II
Electrical shock protection classClass II
Pollution degree3 conforming to IEC 60664-1
IP degree of protectionIP40 conforming to IEC 60529
IK degree of protectionIK07 conforming to IEC 62262
ambient air temperature for operation-25…70 °C
Ambient air temperature for storage-50…85 °C
Relative humidity0…95 %
Operating altitude0...2000 m without derating
2000 m...5000 m with derating

Packing Units
Unit Type of Package 1PCE
Number of Units in Package 11
Package 1 Height7.900 cm
Package 1 Width13.000 cm
Package 1 Length17.600 cm
Package 1 Weight1.285 kg
Unit Type of Package 2S03
Number of Units in Package 212
Package 2 Height30.000 cm
Package 2 Width30.000 cm
Package 2 Length40.000 cm
Package 2 Weight15.820 kg