Range | ComPact |
---|---|
Product name | ComPact NSX |
Range of produc | ComPact NSX100...250 DC ComPact NSX100...250 |
Device short name | NSX100F |
Product or component type | Circuit breaker |
Device application | Distribution |
Number of poles | 2P |
Protected poles description | 2t |
[In] rated current | 100 A at 40 °C |
[Ue] rated operational voltage | 690 V AC 50/60 Hz 500 V DC |
Network type | DC AC |
Network frequency | 50/60 Hz |
Suitability for isolation | Yes conforming to EN/IEC 60947-2 |
utilisation category | Category A |
[Icu] rated ultimate short-circuit breaking capacity | 5 kA Icu at 660/690 V AC 50/60 Hz conforming to IEC 60947-2 36 kA Icu at 250 V DC 1P conforming to IEC 60947-2 36 kA Icu at 125 V DC 1P conforming to IEC 60947-2 36 kA Icu at 500 V DC 2P conforming to IEC 60947-2 10 kA Icu at 500/525 V AC 50/60 Hz conforming to IEC 60947-2 15 kA Icu at 440 V AC 50/60 Hz conforming to IEC 60947-2 18 kA Icu at 380/415 V AC 50/60 Hz conforming to IEC 60947-2 36 kA Icu at 220/240 V AC 50/60 Hz conforming to IEC 60947-2 |
Performance level | F 18 kA 415 V AC |
Trip unit name | TM-D |
Trip unit technology | Thermal-magnetic |
control type | Toggle |
Circuit breaker mounting mode | Fixed |
[Ui] rated insulation voltage | 750 V AC 50/60 Hz conforming to IEC 60947-2 |
---|---|
[Uimp] rated impulse withstand voltage | 8 kV conforming to IEC 60947-2 |
[Ics] rated service short-circuit breaking capacity | 5 kA at 660/690 V AC 50/60 Hz conforming to IEC 60947-2 36 kA at 250 V DC conforming to IEC 60947-2 36 kA at 125 V DC conforming to IEC 60947-2 36 kA at 500 V DC conforming to IEC 60947-2 10 kA at 500/525 V AC 50/60 Hz conforming to IEC 60947-2 15 kA at 440 V AC 50/60 Hz conforming to IEC 60947-2 18 kA at 380/415 V AC 50/60 Hz conforming to IEC 60947-2 36 kA at 220/240 V AC 50/60 Hz conforming to IEC 60947-2 |
Mechanical durability | 20000 cycles |
Electrical durability | 10000 cycles at 277 V In 20000 cycles at 277 V In/2 |
mounting support | Backplate |
Upside connection | Front |
downside connection | Front |
Connection pitch | 35 mm |
Protection type | For overload protection (thermal) for short-circuit protection (magnetic) |
Trip unit rating | 100 A at 40 °C |
Long-time pick-up adjustment type Ir (thermal protection) | Fixed |
[Ir] long-time protection pick-up adjustment range | 1 In |
[Im] magnetic protection pick-up range | 800 A |
earth-leakage protection | Without |
Width (W) | 70 mm |
Height (H) | 161 mm |
Depth (D) | 86 mm |
Standards | EN/IEC 60947 |
---|---|
product certifications | CCC EAC Marine |
Overvoltage category | Class II |
Electrical shock protection class | Class II |
Pollution degree | 3 conforming to IEC 60664-1 |
IP degree of protection | IP40 conforming to IEC 60529 |
IK degree of protection | IK07 conforming to IEC 62262 |
ambient air temperature for operation | -25…70 °C |
Ambient air temperature for storage | -50…85 °C |
Relative humidity | 0…95 % |
Operating altitude | 0...2000 m without derating 2000 m...5000 m with derating |
Unit Type of Package 1 | PCE |
---|---|
Number of Units in Package 1 | 1 |
Package 1 Height | 8.0 cm |
Package 1 Width | 13.2 cm |
Package 1 Length | 17.5 cm |
Package 1 Weight | 1.25 kg |
Unit Type of Package 2 | S03 |
Number of Units in Package 2 | 12 |
Package 2 Height | 30.0 cm |
Package 2 Width | 30.0 cm |
Package 2 Length | 40.0 cm |
Package 2 Weight | 15.487 kg |
Warranty | 18 months |
---|