Measuring principle :Coriolis
Product headline : The robust flowmeter for demanding applications with a compact or remote transmitter. Highest measurement performance for liquids and gases under varying, demanding process conditions.
Sensor features : Highest process safety – immune to fluctuating and harsh environments. Fewer process measuring points – multivariable measurement (flow, density, temperature). Space‐saving installation – no in/outlet run needs. Mass flow: measurement error ±0,05 % (PremiumCal). pressure-rated sensor housing up to 40 bar (580 psi).
Transmitter features : Cost‐effective – dedicated design for standard applications. Safe operation – display provides easy readable process information. Fully industry compliant – IEC/EN/NAMUR. 2‐line backlit display with push buttons. Device in compact or remote version.
Nominal diameter range : DN 8 to 250 (⅜ to 10")
High temperature: DN 25 (1"), DN 50 (2"), DN 80 (3")
Wetted materials : Measuring tube: 1.4539 (904L); 1.4404 (316/316L); Alloy C22, 2.4602 (UNS N06022)
Connection: 1.4404 (316/316L); Alloy C22, 2.4602 (UNS N06022)
Measured variables : Mass flow, density, temperature, volume flow, corrected volume flow, reference density
Max. measurement error :
Mass flow (liquid): ±0.15 % (standard), 0.1 % (option)
Volume flow (liquid): ±0.15 %
Mass flow (gas): ±0.35 %
Density (liquid): ±0.0005 g/cm³
Measuring range : 0 to 2 200 000 kg/h (0 to 80 840 lb/min)
Max. process pressure : PN 100, Class 600, 63K
Medium temperature range :
Standard: –50 to +200 °C (–58 to +392 °F)
High temperature: –50 to +350 °C (–58 to +662 °F)
Ambient temperature range :
Standard: –20 to +60 °C (–4 to +140 °F)
Option: –40 to +60 °C (–40 to +140 °F)
Sensor housing material :1.4301/1.4307 (304L), corrosion resistant
Transmitter housing material : Powder‐coated die‐cast aluminium
1.4301 (304), sheet
CF3M (316L), cast
Degree of protection : IP67, type 4X enclosure. Remote transmitter: IP67, type 4X enclosure
Display/Operation : 2‐line backlit display with push buttons
Configuration via local display and operating tools possible
Outputs :
3 outputs:
0‐20 mA (active)/4‐20 mA (active/passive)
Pulse/frequency/switch output (passive)
Inputs : Status input
Digital communication : HART
PROFIBUS PA
Power supply : DC 16 to 62 V
AC 85 to 260 V (45 to 65 Hz)
AC 20 to 55 V (45 to 65 Hz)
Hazardous area approvals : ATEX, IECEx, FM, CSA, NEPSI
Other approvals and certificates : 3.1 material, calibration performed on accredited calibration facilities (acc. to ISO/IEC 17025), NAMUR, SIL, marine
PED, CRN, AD 2000
3-A, FDA
NACE MR0175/MR0103, PMI; welding test acc. to EN, ASME,NORSOK
Product safety : CE, C-tick, EAC marking
Functional safety : Functional safety according to IEC 61508, applicable in safety-relevant applications in accordance with IEC 61511
Metrological approvals and certificates : Calibration performed on accredited calibration facilities (acc. to ISO/IEC 17025), NAMUR
Marine approvals and certificates : Marine approval
Pressure approvals and certificates : PED, CRN, AD 2000
Material certificates : 3.1 material
NACE MR0175/MR0103, PMI; welding test acc. to EN, ASME,NORSOK
Hygienic approvals and certificates : 3-A, EHEDG, FDA