WaterMaster FEV121 Electromagnetic Flowmeter system, optimised full bore, remote mount
FEV121.050.V.1.S.1.S2.B.1.B.1.A.0.A.2.A.1.A.1-..M5.V3.CWA
050 Bore Diameter - DN 50 (2 in)
FEV121.080.V.1.S.1.S2.B.1.B.1.A.0.A.2.A.1.A.1-..M5.V3.CWA
080 Bore Diameter - DN 80 (3 in)
V Liner Material - Polypropylene (DN 40 … DN 200 only)
S Measuring Electrodes Material - Stainless steel 316Ti (1.4571)
1 Grounding Accessories Standard
S2 Process Connection Type - ISO 7005 PN16 (DN50 ... DN300 only)
B Process Connection Material Carbon steel flanges
1 Usage Certifications Standard (without PED)
B Calibration Type Enhanced accuracy 0.2%
1 Temperature Range Installation / Ambient Temperature Range Standard design / –20 … 60 °C (–4 … 140 °F)
A Language English
0 Signal Cable Length and Type Without signal cable (FEV111 and FEV 191 only)
A Explosion Protection Certification General purpose (non-Ex design)
2 IP67 (NEMA 4X) / IP68 (NEMA 6X) – cable not fitted and not potted (FEV121 and FEV181 only)
A Cable Conduits M20 x 1.5
1 Power Supply 100... 230 V AC, 50 Hz (FEV111 and FEV121 only)
A HART + 20 mA + pulse + contact output
1 Factory defaults / standard diagnostics
M5 Documentation language English
V3 VeriMaster
CWA WRAS cold water approval